[Home ] [Archive]    
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact :: In Press ::
:: Volume 21, Issue 1 (Foll Text in Persian 2009) ::
2009, 21(1): 79-86 Back to browse issues page
Accuracy and validity of spiral conventional tomography in assessment of mandibular implant recipient sites: An in-vitro study
Shahriyar Shahab * , Shokraneh Ghazimoghaddam , Farid Abolhasani , Mohammadjavad Kharazifard , Shahram Namjoy-Nik
Assistant Professor, Oral & Maxillofacial radiology Department, Faculty of Dentistry, Shahed University. Tehran, Iran. , e.mail: sh.shahab@mailcity.co
Abstract:   (8650 Views)

Accuracy and validity of spiral conventional tomography in assessment of mandibular implant recipient sites: An in-vitro study

Dr. Shahab Sh., 1 Dr. Ghazimoghaddam S., 2 Dr. Abolhasani F., 3 Dr. Kharazifard MJ., 4 Dr. Namjoy-Nik S. 5

1 Assistant Professor, Oral & Maxillofacial radiology Department, Faculty of Dentistry, Shahed University. Tehran, Iran. 2 Dentist. 3 Associate Professor, Anatomy Department, Tehran University/Medical Sciences. Tehran. Iran. 4 Biostatistics Consultant, Dental Research Center, Tehran University/ Medical Sciences. Tehran. Iran. 5 Assistant Professor, Oral & Maxillofacial Surgery Department, Faculty of Dentistry, Shahed University. Tehran, Iran.

(Received 26 Feb, 2008 Accepted 14 March, 2009)

Abstract

Background and Aim: Conventional tomography is a cross sectional imaging modality that provides information about the width of the alveolar bone and the position of the critical anatomical structures such as mandibular canal in the lower jaw. In comparison with conventional CT, it is less expensive, more accessible and patients are exposed to much less radiation. The purpose of this study was to compare the accuracy and validity of spiral computed tomography and spiral conventional tomography.

Materials and Methods: Ten fully or partially edentulous cadaver mandibles were selected. The specific points in anterior, canine, premolar, and molar regions were selected and imagings were performed with both radiographic systems. The distance between alveolar crest to superior border of mandibular canal, as well as mandibular height and width were measured by one oral and maxillofacial radiologist in two successive sessions.

Results: The tomography and CT scan (as gold standard) measurements were compared. This evaluation revealed that the absolute mean differences in measuring the vertical dimension in the anterior, canine, premolar, and molar regions were 1.43, 0.74, 0.87, and 0.81 millimeters respectively. The horizontal dimension measurements were 1.21, 0.92, 0.76, and 0.82 millimeters respectively. The absolute mean differences in measuring the vertical and horizontal dimensions were 0.65 and 0.91 millimeters respectively. All these measurements were with in limits of ±1 mm error except in the anterior region. Both measurements of vertical and horizontal dimensions had the tendency to be underestimated in anterior region. In measuring the vertical and horizontal dimensions, the validity of spiral conventional tomography were 90.49% and 73.02% respectively, and both were statistically significant (P < 0.001).

Conclusion: From the results of present study it can be concluded that the spiral conventional tomography is an accurate and reliable technique for measuring the vertical and horizontal dimensions in mandible. Key words: Spiral tomography - Spiral CT scan - Dental implant.

Corresponding Author: Dr. Shahab Sh., Assistant Professor, Oral & Maxillofacial Radiology Department, Faculty of Dentistry, Shahed University. Tehran, Iran.

e.mail: sh.shahab@mailcity.co

Keywords: Spiral tomography, Spiral CT scan, Dental implant.
Full-Text [PDF 267 kb]   (1643 Downloads)    
Type of Study: Research | Subject: General
Send email to the article author

Add your comments about this article
Your username or Email:

Write the security code in the box >


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Shahab S, Ghazimoghaddam S, Abolhasani F, Kharazifard M, Namjoy-Nik S. Accuracy and validity of spiral conventional tomography in assessment of mandibular implant recipient sites: An in-vitro study. The Journal of Islamic Dental Association of IRAN (JIDA) . 2009; 21 (1) :79-86
URL: http://jida.ir/article-1-558-en.html


Volume 21, Issue 1 (Foll Text in Persian 2009) Back to browse issues page
مجله دندانپزشکی جامعه اسلامی دندانپزشکان Journal of Islamic Dental Association of Iran

This work is licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported License which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly

Persian site map - English site map - Created in 0.05 seconds with 31 queries by YEKTAWEB 3638