RT - Journal Article T1 - Dental instrument sterilization status in different packing systems JF - JIDA YR - 2008 JO - JIDA VO - 20 IS - 2 UR - http://jida.ir/article-1-343-en.html SP - 140 EP - 144 K1 - Sterilization K1 - Autoclave K1 - Sterile pouch K1 - Culture. AB - Dental instrument sterilization status in different packing systems Dr. Sadat-Mansuori S., 1 Dr. Ghasemi M., 1 Dr. Amir-Behboodi T., 2 Dr. Pournasir K.2 1Associate professor, Department of Periodontology, Islamic Azad University, Dental branch, Tehran, Iran. 2Dentist. Abstract Background & Aim: A thorough knowledge about the shelf life of various types of instrument packing is necessary in order to avoid unnecessary re-sterilization of dental instruments. The aim of this study was to evaluate the shelf life of five commonly used packing systems in routine dental practice. Materials & Methods: This experimental study was conducted with 1400 orthodontic wires. They were divided into five groups (n=280) in order to be packed by Steriperfect (St), TECNO-GAZ (TG), SOGEVA (SO), E-Line (E) and linen (L) brand materials. These packs were then stored in an active dental office environment after proper sterilization by autoclave. Forty packs of each group underwent culture test at 7 different time intervals of 0, 1, 2.5, 4.5, 7 and 9 months. Fisher’s exact test was used to compare group differences. Results: Only 5 packs of L, 6 of St, 3 of TG, 1 of SO and 2 of E showed positive culture results at 0 month samples. Likewise positive culture results were reported for 2 of (L), 1 of (St), 2 of (TG), 3 of (SO) and 1 of (E) in the first month. No significant difference was detected among different packing materials. Conclusion: The findings of this study support the previous findings that contamination is more of event related, not time related meaning that, sterile instrument packs remain sterile for at least 9 months unless the integrity of pack is violated. Key words: Sterilization - Autoclave - Sterile pouch - Culture. Corresponding Author: Dr. Sadat-Mansuori S., Department of Periodontology, Islamic Azad University, Dental branch, Tehran, Iran. e.mail: Saeed_sadat mansouri@yahoo.com LA eng UL http://jida.ir/article-1-343-en.html M3 ER -