﻿<?xml version="1.0" encoding="UTF-8"?>
<ArticleSet>
  <Article>
    <Journal>
      <PublisherName>Iranian Dental Association</PublisherName>
      <JournalTitle>Journal of Iranian Dental Association</JournalTitle>
      <Issn>3060-8201</Issn>
      <Volume>31</Volume>
      <Issue>3</Issue>
      <PubDate PubStatus="ppublish">
        <Year>2019</Year>
        <Month>07</Month>
        <DAY>01</DAY>
      </PubDate>
    </Journal>
    <ArticleTitle>Comparison of Water Sorption of Two Injection Acrylic Resins with a Conventional Pressure-Packed Acrylic Resin</ArticleTitle>
    <FirstPage>177</FirstPage>
    <LastPage>181</LastPage>
    <ELocationID EIdType="doi">10.30699/jidai.31.3.177</ELocationID>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName>Ehsan</FirstName>
        <LastName>Ghasemi</LastName>
      </Author>
      <Author>
        <FirstName>Ramin</FirstName>
        <LastName>Mosharraf</LastName>
      </Author>
      <Author>
        <FirstName>Siavash</FirstName>
        <LastName>Mirzaei</LastName>
      </Author>
    </AuthorList>
    <PublicationType>Journal Article</PublicationType>
    <ArticleIdList>
      <ArticleId IdType="doi">10.30699/jidai.31.3.177</ArticleId>
    </ArticleIdList>
    <History>
      <PubDate PubStatus="received">
        <Year>2020</Year>
        <Month>02</Month>
        <Day>23</Day>
      </PubDate>
      <PubDate PubStatus="accepted">
        <Year>2020</Year>
        <Month>02</Month>
        <Day>23</Day>
      </PubDate>
    </History>
    <Abstract>Background and Aim: Water sorption is one of the most important properties that affects the quality of a prosthesis, and subsequently, the quality of treatment, and pa-tient’s quality of life. The aim of this study was to determine and compare the water sorption of two types of poly methyl methacrylate (PMMA) using the injection-molding systems with a traditional acrylic resin base material.&lt;br&gt; Materials and Methods: In this in vitro, experimental study, three groups of PMMA (n=10), consisting of two groups of injection molded PMMA samples (Vertex Castavar-ia and Ivo-Base High-Impact) were used for two different injection molding techniques and one group of conventional pressure-packed PMMA (Meliodent Heat Cure) was used for the conventional pressure-packed technique. After processing, 30 specimens were stored in distilled water at 37°C for 30 days. The water sorption test was then performed. Statistical analysis was carried out using SPSS version 23.0 via the Krus-kal-Wallis and Mann-Whitney tests (α=0.05).&lt;br&gt; Results: The mean value of water sorption was 17.88±1.08 µg/mm3 for IvoBase spec-imens, 28.45±2.19µg/mm3 for Vertex specimens, and 21.76 ±3.26 µg/mm3 for Melio-dent specimens (P&lt;0.001 for Ivobase-Vertex, P &lt;0.007 for Ivobase-Meliodent, and P&lt;0.001 for Vertex-Meliodent).&lt;br&gt; Conclusion: Water sorption of IvoBase was significantly lower than that of other ma-terials. Despite such a significant difference, all of them completely fulfilled the re-quirements of EN ISO 20795-1:2008.</Abstract>
  </Article>
</ArticleSet>