[Home ] [Archive]    
:: Main :: About :: Current Issue :: Archive :: Search :: Submit ::
Main Menu
Journal Information::
Editorial Policies::
Articles archive::
For Authors::
Contact us::
Site Facilities::
::
Search in website

Advanced Search
Receive site information
Enter your Email in the following box to receive the site news and information.
Last site contents
:: Contact Us
:: Volume 31, Issue 3 (7-2019) ::
J Iran Dent Assoc 2019, 31(3): 169-176 Back to browse issues page
Effect of Three Disinfectants on Dimensional Changes of Different Impression Materials
Ehsan Ghasemi1 , Amir Hossein Fathi * 2, Sara Parvizinia3
1- Assistant Professor, Dental Material Research Center, Department of Prosthodontics, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran
2- Assistant Professor, Dental Material Research Center, Department of Prosthodontics, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran , amir_alty@yahoo.com
3- Dentist, Private Office, Isfahan, Iran
Abstract:   (3283 Views)
Background and Aim: Disinfection of dental impression materials can alter their dimensional stability, which in turn can affect the accuracy of dental casts. This study aimed to determine the effect of three disinfectants on the dimensional changes of ir-reversible hydrocolloid impression materials and addition silicones.
Materials and Methods: Forty alginate and 40 addition silicone impressions were made using special trays. The impressions were disinfected by the spraying method for 10 minutes except for the control group. Then, they were poured with type IV den-tal stone. The prepared casts were maintained for 24 hours in a similar condition. Next, the dimensions and the external distance between two dies were measured at three time intervals using a digital caliper with 0.01 mm accuracy, and the average values were recorded. The yielded measurements were compared with each other and with metal models. One-way ANOVA and one sample t-test (α=0.05) were used for data analysis.
Results: No significant difference was observed between the groups (P>0.05). Com-parison of all average dimensions of the casts with the metal model showed that none of the groups had a significant difference except for the alginate group that showed an increase in the height of the larger die. There was a significant difference in the rest of the dimensions (P<0.05).
Conclusion: Disinfection of alginate and addition silicone impression materials with 0.5% sodium hypochlorite, Epimax, and Deconex did not have any significant effect on the cast dimensions.
Keywords: Colloids, Dental impression materials, Dental disinfectants
Full-Text [PDF 628 kb]   (1663 Downloads)    
Type of Study: Original | Subject: Prosthodontics
References
1. Donovan TE, Chee WW. A review of contemporary impression materials and techniques. Dent Clin North Am. 2004 Apr;48 (2):vi-vii, 445-70.
2. Hamalian TA, Nasr E, Chidiac JJ. Impression ma-terials in fixed prosthodontics: influence of choice on clinical procedure. J Prosthodont. 2011 Feb;20(2):153-60.
3. Cervino G, Fiorillo L, Herford A, Laino L, Troiano G, Amoroso G, et al. Alginate materials and den-tal impression technique: A current state of the art and application to dental practice. Mar drugs. 2019 Jan;17(1):18.
4. Kohn WG, Collins AS, Cleveland JL, Harte JA, Eklund KJ, Malvitz DM. Guidelines for infection control in dental health-care settings-2003. December 19, 2003/ 52(RR17);1-61.
5. Mantena SR, Mohd I, Sajjan S, Ramaraju A. Disin-fection of impression materials: A comprehensive review of disinfection methods. Int J Dent Mater. 2019; 1(1):07-16.
6. Taylor RL, Wright PS, Maryan C. Disinfection procedures: their effect on the dimensional accuracy and surface quality of irreversible hydrocolloid impression materials and gypsum casts. Dent Mater. 2002 Mar;18(2):103-10.
7. Suprono MS, Kattadiyil MT, Goodacre CJ, Winer MS. Effect of disinfection on irreversible hydro-colloid and alternative impression materials and the resultant gypsum casts. J Pros-thet Dent. 2012 Oct;108(4):250-8.
8. Silva SM, Salvador MC. Effect of the disinfection technique on the linear dimensional stability of dental impression materials. J Appl Oral Sci. 2004 Sep;12(3):244-9.
9. Badrian H, Ghasemi E, Khalighinejad N, Hosseini N. The effect of three different disinfection materials on alginate impression by spray method. ISRN Dent. 2012;2012:695151.
10. Giblin J, Podesta R, White J. Dimensional stabil-ity of impression materials immersed in an iodophor disinfectant. Int J Prosthodont. 1990 Jan-Feb;3(1):72-7.
11. Beyerle MP, Hensley DM, Bradley Jr DV, Schwartz RS, Hilton TJ. Immersion disinfection of irreversible hydrocolloid impressions with sodium hypochlorite. Part I: Microbiology. Int J Prosthodont. 1994; 7(3):234-238.
12. Memarian M, Zare M. The effed of sodium hypo-chlorite on irreversible hydrocolloid and thier effeds on dimmentional stability and detail re-produdion of resultant gypsom casts. J Islam Dent Asso Ir. 2002 Summer; 14(2):70-81.
13. Rentzia A, Coleman DC, O'Donnell MJ, Dowling AH, O'Sullivan M. Disinfection procedures: their efficacy and effect on dimensional accuracy and surface quality of an irreversible hydrocolloid impression material. J Dent. 2011 Feb;39(2):133-40.
14. Martin N, Martin MV, Jedynakiewicz NM. The dimensional stability of dental impression materials following immersion in disinfecting solutions. Dent Mater. 2007 Jun;23(6):760-8.
15. Chew CL, Chee WW, Donovan TE. The influence of temperature on the dimensional stability of poly (vinyl siloxane) impression materials. Int J Prosthodont. 1993 Nov-Dec; 6 (6):528-32.
16. Walker MP, Petrie CS, Haj‐Ali R, Spencer P, Du-mas C, Williams K. Moisture effect on polyether and polyvinylsiloxane dimensional accuracy and detail reproduction. J Prostho-dont. 2005 Sep;14(3):158-63.
17. Ghasemi E, Ebadian B, Badrian H, Asad A. Effect of storage time on dimensional changes of irre-versible hydrocolloid impression material. J Is-fahan Dent Sch. 2012; 7(5):585–91.
18. Mosharraf R, Nosouhian S, Salehi M. Effect of storage time on dimensional stability of Extended-pour irreversible hydrocolloid impression material. J Isfahan Dent Sch. 2011 Fall;7(3):246-255.
19. Corso M, Abanomy A, Di Canzio J, Zurakowski D, Morgano SM. The effect of temperature changes on the dimensional stability of polyvinyl siloxane and polyether impression materials. J Prosthet Dent. 1998 Jun; 79(6):626-31.
20. Durr D, Novak EV. Dimensional stability of algi-nate impressions immersed in disinfecting solu-tions. ASDC J Dent for Child. 1987 Jan;54 (1):45-8.
21. Powers JM, Wataha JC. Dental Materials: Proper-ties and Manipulation 10th edition Mosby. St Louis, Mo. 2013:15-21.
22. Badrian H, Davoudi A, Molazem M, Zare MH. The effect of spraying different disinfectants on condensational silicone impressions; an in vitro study. J Indian Prosthodont Soc. 2015 Jul-Sep; 15(3):263-7.
23. Tan H-K, Hooper PM, Buttar IA, Wolfaardt JF. Effects of disinfecting irreversible hydrocolloid impressions on the resultant gypsum casts: Part II-Dimensional changes. J Prosthetic Dent. 1993 Dec; 70(6):532-537.
24. Hamedi Rad F, Ghaffari T, Safavi SH. In vitro evaluation of dimensional stability of alginate impressions after disinfection by spray and immersion methods. J Dent Res Dent Clin Dent Prospects. 2010 Fall;4(4):130-5.
25. Melilli D, Rallo A, Cassaro A, Pizzo G. The effect of immersion disinfection procedures on di-mensional stability of two elastomeric impression materials. J Oral Sci. 2008 Dec;50 (4):441-6.
26. Materials CoD, Devices. Revised American Den-tal Association specification No. 19 for non-aqueous, elastomeric dental impression materials. J Am Dent Assoc. 1977 Apr;94(4):733-41.
27. Hiraguchi H, Kaketani M, Hirose H, Yoneyama T. The influence of storing alginate impressions sprayed with disinfectant on dimensional accuracy and deformation of maxillary edentulous stone models. Dent Mater J. 2010 May;29(3):309-15.
28. al-Omari WM, Jones JC, Wood DJ. The effect of disinfecting alginate and addition cured silicone rubber impression materials on the physical properties of impressions and resultant casts. Eur J Prosthodont Restor Dent. 1998 Sep;6(3):103-10.
29. Herrera SP, Merchant VA. Dimensional stability of dental impressions after immersion disinfection. J of ADA. 1986;113(3):419-22.
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA



XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Ghasemi E, Fathi A H, Parvizinia S. Effect of Three Disinfectants on Dimensional Changes of Different Impression Materials. J Iran Dent Assoc 2019; 31 (3) :169-176
URL: http://jida.ir/article-1-2055-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 31, Issue 3 (7-2019) Back to browse issues page
Journal of Iranian Dental Association

AWT IMAGE

This work is licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported License which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly

Persian site map - English site map - Created in 0.05 seconds with 37 queries by YEKTAWEB 4645