J Iran Dent Assoc 2014, 26(3): 177-183 Back to browse issues page
Diagnostic Accuracy of Digital Phosphor Plates Using Pseudo-Color Enhancement for Detection of Horizontal Root Fractures in Single-Rooted Teeth
Sandra Mehralizadeh1 , Sahar Mohammadi * 2, Ahmadreza Talaeepour3 , Peaiman Mehrvarzfar4 , Maryam Mirzaee5
1- Assistant Professor, Department of Oral & Maxillofacial Radiology, School of Dentistry, Islamic Azad University. Tehran, Iran
2- Department of Oral & Maxillofacial Radiologist, School of Dentistry, shaheed beheshty University of Medical Sciences, Tehran, Iran , drsaharmohammadi88@gmail.com
3- Professor, Department of Oral & Maxillofacial Radiology, School of Dentistry, Islamic Azad University. Tehran, Iran
4- Associate Professor, Department of Endodontics, School of Dentistry, Islamic Azad University. Tehran, Iran
5- Oral & Maxillofacial Radiologist
Abstract:   (9612 Views)

  Background and Aim : If root fractures remain undetected, pulp necrosis will occur in 25% of cases leading to eventual tooth loss. The purpose of this study was to evaluate the diagnostic accuracy of digital phosphor plates using pseudo-color enhancement for detection of horizontal root fractures in single-rooted teeth .

  Materials and Methods : Eighty-two human single-rooted teeth were evaluated (41 with no horizontal fracture and 41 with horizontal fractures). Digital intraoral imaging plate system.

  (Digora® Optime PSP System, Soredex) was used to obtain 16-bit gray scale images. Five 16-bit images were obtained from each specimen and saved (one original and four with pseudo-color enhancement). Four observers evaluated the images twice with a 2-week interval. Accuracy, positive predictive value (PPV), negative predictive value (NPV), specificity and sensitivity for each observer and each image group were calculated .

  Results : The diagnostic sensitivities were not significantly different among the five images (p absolute=0.125 , p complete=0.170). But, statistically significant differences were found in the diagnostic specificity (p absolute=0.019, p complete=0.016) among the five views. Cool and Summer views had higher diagnostic specificity than Bone, Copper and Original views (p=0.025). Kappa and Weighted Kappa values showed statistically significant differences for intra- and inter-observer reliability in the five views (p=0.032).

  Conclusion : Both Cool and Summer views were suitable for detection of horizontal root fractures and had statistically significant differences with the original view . 

Keywords: Dental digital radiography, Image enhancement, Tooth fracture detection
Full-Text [PDF 191 kb]   (2258 Downloads)    
Type of Study: Original | Subject: Oral and Maxillofacial Radiology
References
1. Versiani MA, de Sousa CJ, Cruz-Filho AM, Pe-rez DE, Sousa-Neto MD. Clinical management and subsequent healing of teeth with horizontal root fractures. Dent Traumatol. 2008 Feb; 24(1):136-9.
2. Molina JR, Vann WF Jr, McIntyre JD, Trope M, Lee JY. Root fractures in children and adoles-cent: Diagnostic consideration. Dent Traumatol. 2008 Oct;24(5):503-9.
3. Kamburoğlu K, Ilker Cebeci AR, Gröndahl HG. Effectiveness of limited cone-beam computed tomography in the detection of horizontal root fracture. Dent Traumatol. 2009 Jun;25(3):256-261.
4. Takeuchi N, Yamamoto T, Tomofuji T, Mura-kami C. A retrospective study on the prognosis of teeth with root fracture in patients during the maintenance phase of periodontal therapy. Dent Traumatol. 2009 Jun; 25(3):332-7.
5. Bornstein MM, Wölner-Hanssen AB, Sendi P, von Arx T. Comparison of intraoral radiog-raphy and limited cone beam computed to-mography for the assessment of root fractured permanent teeth. Dent Traumatol. 2009 Dec; 25(6):571-7.
6. Nair MK, Nair UP, Grondahl H-G, Webber RL, Wallace JA. Detection of artificially in-duced vertical radicular fractures using tuned Aperture computed tomography. Eur J Oral Sci. 2001 Dec; 109(6):375-79.
7. Iikubo M, Kobayashi K, Mishima A, Shimoda S, Daimaruya T, Igarashi C, et al. Accuracy in-traoral radiography, multidetector helical Ct, and limited cone–beam CT for the detection of horizontal tooth root fracture. Oral Surg Oral Med Oral Phathol Oral Radiol Endod. 2009 Nov; 108 (5):70-4.
8. Nair MK, Nair UP, Grondahi HG, Webber RL. Accuracy of tuned aperture computed tomog-raphy in the diagnosis of radicular fractures in nonrestored maxillary anterior teeth: An in vitro study. Dentomaxillofac Radiol. 2002 Sept;31 (5):299-304.
9. Wenzel A, Haiter-Neto F, Frydenberg M, Kirkevang LL. Variable resolution cone-beam computerized tomography with enhancement filtra-tion compared with intraoral photostimulable phosphor radiography in detection of transverse root fractures in an in vitro model. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2009 Dec; 108(6): 939-45.
10. Costa FF, Gaia BF, Umetsubo OS, Cavalcanti MG. Detection of horizontal root fracture with small-volume cone-beam computed tomogra-phy in the presence and absence of intracanal metallic post. J Endod. 2011 Oct;37(10):1456-9.
11. Kositbowornchai S, Nuansakul R, Sikram S, Sinahawattana S, Saengmontri S. Root fracture detection: A comparison of direct digital radi-ography with conventional radiography. Den-to -maxillofac Radiol. 2001 Mar;30(2):106-9.
12. Syriopoulos K, Sanderink GC, Velders XL, van der Stelt PF. Radiographic detection of aproximal caries: A comparison of dental film and digital imaging system. Dentomaxillofac Radiol. 2000 Sept; 29(5):312-8.
13. Haiter-Neto F, Casanova MS, Frydenberg M, Wenzel A. Task-specific enhancement filters in storage phosphor images from the vistascan system for detection of proximal caries le-sions of known size. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2009 Jan;107(1):116-21.
14. Ramanathan GP. Diagnosis of caries: A com-parison of three radiograph viewing tech-niques. J Clin Pediatr Dent. 1999 Spring; 23(3): 235-45.
15. Versteeg CH, Sanderink GC, van der Stelt PF. Efficacy of digital intraoral radiography in clinical dentistry. J Dent. 1997 May-Jul; 25(3-4):215-24.
16. Vander Stelt PF. Filmless imaging: The uses of digital radiography in dental practice. J Am Dent Assoc. 2005 Oct;136(10):1379-87.
17. Berkhout WE, Beuger DA, Sandeink GC, Van Der Stelt PF. The dynamic range of digital ra-diographic system: Dose reduction or risk of overexposure? Dentomaxillofac Radiol. 2004 Jan;33(1):1-5.
18. Alpöz E, Soğur E, Baksi Akdeniz BG. perceptil-ity curve test for digital radiography before pro-cessing algorithms. Dentomaxillofac Radiol. 2007 Dec; 36(8):490-4.
19. LU Xiang Ju, DING Ming-Xiao, WANG Yun-Kuan. A new pseudo color transform for fiber masses inspection of industrial images. Acta Automatica Sinica. 2009 Mar; 35(3):233-38.
20. Ryan B. Wiesemann, James P. Scheetz, Ani-bal M. Silveira, Taeko T. Farman, and Allan G. Farman. Cephalometric landmark clarity in photostimulable phosphor images using pseu-do color and emboss enhancements. Int J CARS. 2006 Aug; 1(2):105-112.
21. Tsesis I, Kamburoglu K, Katz A, Tames A, Kaffe I, Kfire A. Comparison of digital with conventional radiography in detection of ver-tical root fractures in endodontically treated maxillary premolars: an ex vivo study. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2008 Jul; 106 (1):124-8.
22. Lee JU, Kwon KJ, Koh KJ. Diagnostic accu-racy of artificially induced vertical root frac-tures: A comparison of direct digital periapical images with conventional periapical images. Korean Oral Maxillofac Radiol. 2004 Dec;34(4):185-90.
23. Bushong Stewart C. Radiologic science for technologists. 9th ed. Canada: Mos-by;2008,180-92.
24. Kositboeornchai S, Sikram S, Nuansakul R, Thinkhamrop B. Root fracture detection on digital images: Effect of zoom function. Dent Traumatol. 2003 Jun; 19(3):154-9.
25. Wenzel A, Kirkevang LL. High resolution charge coupled device sensor vs medium resolution photostimulable phosphor plate dig-ital receptors for detection of root fractures in vitro. Dent Traumatol. 2005 Feb; 21(1):32-36.
26. Yoshiura K, Kawazu T, Chikui T, Tatsumi M, Tokumori K, Tanaka T, et al. Assessment of image quality in dental radiography, part 2: Optimum exposure condition for detection of small mass changes in 6 intraoral radiography system. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 1999 Jan;87(1):123-9.
27. Furkart AJ, Dove SB, McDavid WD, Nummikoski P, Matteson S. Direct digital radiography for the detec-tion of periodontal bone lesions. Oral Surg Oral Med Oral Pathol. 1992 Nov; 74(5);652-60.
28. Møystad A, Svanaes DB, Larheim TA, Gröndahl HG. Effect of image magnification of digitized bitewing radiographs on approximal caries detec-tion: an in vitro study. Dentomaxillofac Radiol. 1995 Nov;24(4):255-9.
29. Reddy MS, Bruch JM, Jeffcoat MK, Williams RC. Contrast as an aid to interpretation in dig-ital subtraction radiography. Oral Surg Oral Med Oral Pathol. 1991 Jan; 71(6):763-769.
30. Scarfe WC, Czerniejewski VJ, Farman AG, Avant SL, Molteni R. In vivo accuracy and reli-ability of color-coded image enhancements for the assessment of periradicular dimensions. Oral Surg Oral Med Oral Pathol Oral Radiol En-dod. 1999 Nov; 88(5):603-611.
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Mehralizadeh S, Mohammadi S, Talaeepour A, Mehrvarzfar P, Mirzaee M. Diagnostic Accuracy of Digital Phosphor Plates Using Pseudo-Color Enhancement for Detection of Horizontal Root Fractures in Single-Rooted Teeth. J Iran Dent Assoc 2014; 26 (3) :177-183
URL: http://jida.ir/article-1-1646-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 26, Issue 3 (7-2014) Back to browse issues page
Journal of Iranian Dental Association

AWT IMAGE

This work is licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported License which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly

Persian site map - English site map - Created in 0.04 seconds with 37 queries by YEKTAWEB 4645