Journal of Iranian Dental Association
J Iran Dent Assoc
Medical Sciences
http://jida.ir
23
journal23
2383-3041
10.52547/jida
en
jalali
1390
9
1
gregorian
2011
12
1
23
4
online
1
fulltext
fa
ارزیابی دقت دو آپکس یاب الکترونیکی Foramatron V و Ipex در تعیین طول کانال ریشه دندان
An in vitro evaluation of the accuracy of two electronic apex locators Foramatron V and Ipex in determining working length
Endodontics
Endodontics
Research
Research
<p align="center"> <strong> ارزیابی دقت دو آپکس یاب الکترونیکی </strong><strong>Foramatron V </strong><strong>و </strong><strong>Ipex </strong><strong>در تعیین طول </strong></p><p align="center"> <strong> کانال ریشه دندان </strong></p><p> <strong><u> </u></strong></p><p> <strong> </strong></p><p align="right"> <strong> دکتر محمدحسن ضرابی<sup>1</sup>- دکتر فاطمه شهرامی<sup>2 </sup>- <u>دکتر مریم قره چاهی<sup>3</sup></u> </strong><strong>– </strong><strong>دکتر مریم فرقانی <sup>3</sup>- دکتر مهدی وطن پور<sup>4</sup> </strong><strong></strong></p><p align="right"> 1- استاد گروه آموزشی اندودنتیکس دانشکده و عضو مرکز تحقیقات دندانپزشکی دانشگاه علوم پزشکی مشهد </p><p align="right"> 2- اندودنتیست </p><p align="right"> 3- استادیار گروه آموزشی اندودنتیکس دانشکده دندانپزشکی دانشگاه علوم پزشکی مشهد </p><p align="right"> 4- استادیار گروه آموزشی اندودنتیکس دانشکده دندانپزشکی دانشگاه آزاد اسلامی تهران </p><p align="right"> </p><p> </p><p align="justify"> <strong> چکیده </strong><strong></strong></p><p align="justify"> <strong><em> زمینه و هدف : </em></strong>تعیین دقیق طول کارکرد در درمان ریشه دندان از اهمیت ویژهای در موفقیت درمان برخوردار است. روشهای مختلفی برای محاسبه طول کارکرد ارائه شده است که از آن جمله میتوان به استفاده از دستگاههای آپکس یاب الکترونیکی اشاره کرد. هدف از این مطالعه آزمایشگاهی، مقایسه دقت دو آپکس یاب الکترونیکی Foramatron V و Ipex در تعیین طول کانال دندانهای تک ریشه انسان میباشد. </p><p align="justify"> <em><strong> روش بررسی:</strong></em> در این مطالعه که به روش آزمایشگاهی انجام شد از صد دندان تک ریشه و تک کانال انسیزور فک بالا با آپکس تکامل یافته بدون انحنای ریشه استفاده شد. دندانها پس از خارج شدن تمیز و تا زمان انجام آزمایش در نرمال سالین نگهداری شدند. پس از کد گذاری دندانها و تهیه حفره دسترسی، طول واقعی هرکانال به روش آناتومیک و با بردن K فایل در کانال و قرار دادن آن در وضعیت نوک به نوک با فورامن آپیکال، ثبت گردید. پس از تهیه محیط آزمایش، دندانها تا ناحیه CEJ در محیط قرار داده شدند و طول کانال دندانها با توجه به شماره کد آن، توسط دستگاه Ipex و Foramatron V اندازهگیری شد. محدوده مورد قبول در این مطالعه، 5/0 ± نسبت به طول واقعی کانال بود. پس از جمع آوری اطلاعات به دست آمده، از تست Paired t-test و Mac Nemar جهت ارزیابی آماری استفاده شد. </p><p align="justify"> <strong><em> یافتهها:</em></strong> بر اساس نتایج به دست آمده از این مطالعه</p><p align="justify">، Foramatron V در 48% موارد و دستگاه Ipex در 34% موارد اندازهگیری را در آپیکال فورامن نشان داد. در محدوده 0 - 5/0 میلی متر کوتاهتر از آپیکال فورامن (0 - 5/0 میلیمتر)، دقت Ipex ، 42% و دقت Foramatron V ، 56% گردید. در 21% موارد، Ipex طول صفر تا نیم میلی متر بیشتر از آپیکال فورامن را ثبت کرد که در مورد Foramatron V ، 8% بود. بنابراین میزان دقت دستگاه Foramatron V در محدوده 5/0 ± میلیمتر نسبت به طول واقعی کانال 64% و دقت دستگاه Ipex در این محدوده 63% بود که اختلاف بین این دو دستگاه از لحاظ آماری معنیدار نبود. (0001/0 < P ) </p><p align="justify"> <strong><em> نتیجهگیری:</em></strong> بر اساس نتایج به دست آمده، تفاوت معنیداری بین میزان دقت دو دستگاه آپکس یاب </p><p align="justify">Ipex و Foramatron V وجود نداشت. لذا میتوان از دستگاه Foramatron V ساخت داخل به عنوان یکی از ابزارهای تعیین طول کارکرد استفاده کرد. </p><p align="justify"> <strong><em> کلید واژهها:</em></strong> آپکس لوکیتور – طول کارکرد اندودنتیک – درمان ریشه دندان </p><p align="justify"> وصول مقاله: 10/12/1389 /1383 اصلاح نهایی: 21/3/1390 پذیرش مقاله: 9/5/1390 /1385 </p><p align="justify"> <strong><u> نویسنده مسئول </u></strong><strong>: </strong>دکتر مریم قره چاهی، گروه آموزشی اندودنتیکس دانشکده دندانپزشکی دانشگاه علوم پزشکی مشهد </p><p align="justify"> e.mail: <a href="mailto:gharechahim@mums.ac.ir"><u>gharechahim@mums.ac.ir</u></a> </p>
<p align="center"> <strong>An in vitro evaluation of the accuracy of two electronic apex locators Foramatron V and Ipex in determining working length</strong> </p><p> <strong><i> </i></strong><strong><i /></strong></p><p align="center"> <strong> Dr. </strong><strong>Zarrabi </strong><strong>MH.,<sup>1</sup> </strong><strong>Dr. </strong><strong>Shahrami </strong><strong>F </strong><strong>.,<sup>2 </sup><u>Dr. </u></strong><strong><u>Gharechahi </u></strong><strong><u>M., </u></strong><strong><sup>3 </sup></strong><strong>Dr. </strong><strong>Forghani </strong><strong>M.,<sup>3</sup> Dr. </strong><strong>Vatan pour </strong><strong>M. <sup>4</sup> </strong></p><p align="center"> <strong> </strong></p><p align="center"> <strong><sup> 1 </sup></strong>Professor , <sup />Department of Endodontics , School of Dentistry, Mashhad University of Medical Sciences. Mashhad , Iran . <strong><sup>2 </sup></strong>Endodontist . <strong></strong><strong><sup>3 </sup></strong><strong></strong>Assistant <strong></strong>Professor , Department of Endodontics , School of Dentistry, Mashhad University of Medical Sciences. Mashhad , Iran . <strong><sup /></strong><strong><sup>4 </sup></strong>Assistant <strong></strong>Professor , Department of Endodontics , School of Dentistry, Islamic Azad University. Tehran, Iran . </p><p align="center"> <strong><i> </i></strong></p><p align="center"> <strong><i> (Received </i></strong><strong><i /></strong><strong><i>7 March, 2011 Accepted </i></strong><strong><i /></strong><strong><i>31 July, 2011) </i></strong></p><p> <strong><i> </i></strong></p><p> <strong><i> Abstract </i></strong></p><p> <strong><i><sup> </sup></i></strong></p><p> <strong> Background and Aim </strong><strong>: </strong>Accurate determination of working length in root canal therapy is very important for success of the process. Different methods such as electronic apex locators have been introduced for determination of working length. The aim of this in vitro study was comparison of the accuracy of two electronic apex locators, Foramatron V and Ipex, in determination of working length in human single root teeth. </p><p> <strong> Materials and Methods </strong><strong>: </strong>In this in vitro study, 100 human single root, single canal maxillary incisors with developed apex without curve were used. The teeth were cleaned after extraction and stored in normal salin. After preparing access cavity, the actual length of each canal was determined by an anatomic method placing a k-file into the canal so that the file tip touched the apical foramen. After preparing the experimental environment, the teeth were placed in the model at the level of CEJ and the length of the teeth were determind with Ipex and Formatron V according to their code. The acceptable limitation was ±0.5 millimeter to the actual working length. After collection of data, Mac Nemar and Paired t-test were used for statistical analysis. </p><p> <strong> Results: </strong>According to the results of this study, the accuracy of length determination was 64% and 63% for Foramatron V and ipex, respectively in the range of canal length±0.5 mm. There was no significant statistical difference between these two devices. <strong><i /></strong></p><p> <strong> Conclusion </strong><strong>: </strong>There was no significant difference between Ipex and Foramatron V. Therefore, Foramatron V may be used for working length determination. <strong><i /></strong></p><p> <strong><i>Key words</i>: </strong><strong></strong>Apex locator - Endodontic working length - Ipex - Foramatron V </p><p> <strong><i> </i></strong></p><p> <strong><i> Corresponding Author: </i></strong><i>Dr. </i><i>Gharechahi </i><i>M </i><i>., </i><i>Assistant </i><strong><i /></strong><i>Professor </i><i>, </i><i>Department of </i><i /><i>Endodontics </i><i>, </i><i>School of Dentistry, </i><i /><i>Mashhad </i><i>University of Medical Sciences. </i><i>Mashhad </i><i>, Iran </i><i>. </i><strong><i><sup /></i></strong><strong><i /></strong></p><p> <strong><i> e.mail: </i></strong><i /><a href="mailto:Gharechahim@mums.ac.ir"><i><u>Gharechahim@mums.ac.ir</u> </i></a><strong><i /></strong></p>
آپکس لوکیتور ، طول کارکرد اندودنتیک ، درمان ریشه دندان
Apex locator , Endodontic working length , Ipex , Foramatron V
232
238
http://jida.ir/browse.php?a_code=A-10-1-595&slc_lang=fa&sid=1
Mahammad hasan
Zarrabi
دکتر محمدحسن
ضرابی
230031947532846007160
230031947532846007160
No
Fateme
Shahrami
دکتر فاطمه
شهرامی
230031947532846007161
230031947532846007161
No
maryam
Gharechahi
دکتر مریم
قره چاهی
gharechahim@mums.ac.ir
230031947532846007162
230031947532846007162
Yes
maryam
Forghani
دکتر مریم
فرقانی
230031947532846007163
230031947532846007163
No
Mahdi
Vatan pour
دکتر مهدی
وطن پور
230031947532846007164
230031947532846007164
No