:: Volume 18, Issue 2 (Foll Text in Persian 2006) ::
J Iran Dent Assoc 2006, 18(2): 72-80 Back to browse issues page
In vitro biocompatibility of eight orthodontic materials in human oral fibroblasts
Sosan Sadeghian * 1, Mohammad hosein Nasr Esfahani , Fariba Molavi
1- , drsadeghian@yahoo.com
Abstract:   (21503 Views)

In vitro biocompatibility of eight orthodontic materials in human oral fibroblasts

Dr. S. Sadeghian* - Dr. MH. Nasr Esfahani** - F. Molavi***

 *- Assistant Professor of Orthodontics Dept. - Faculty of Dentistry – Islamic Azad University (Khorasgan).

**- Associate Professor of Embryology, Royan Institute,

***- Member of Royan Institute,

Background and Aim: In orthodontic therapy, different materials are used and subjected to a damp oral environment, which can modify their properties. The purpose of this study was to evaluate the biocompatibility of eight metallic and non metallic orthodontic materials in human oral fibroblast culture.

 Materials and Methods: The specimens consisted of eight clinically used materials, including two coil springs, two glass ionomer cements, two O-rings and two orthodontic acrylic resins. Teflon was used as a negative control. After a release period of each material in the culture medium for 20 days, the viability of oral cultivated fibroblasts was compared to the negative control by MTT assay. Biocompatibility was also assessed using the direct method in which cell viability was evaluated by an invert phase contrast microscope, after direct exposure to the tested materials.

Results: MTT assay showed stainless steel (P.V=0.665) and Bayer acrylic resin (P.V=0.179) to be biocompatible with gingival fibroblasts. Significant differences were observed between the biocompatibility of all study groups [Nickel titanium (PV=0.037), Acropars acrylic resin (PV=0.014) and both studied O-rings (PV=0.001), (PV=0.016)] and the control group. According to the direct method, stainless steel and Nickel titanium showed grade 1, glass ionomer cements grade 4 and other materials revealed grade 0 cytotoxicity.

 Conclusion: The two studied glass ionomer cements were highly cytotoxic. Bayer acrylic resin was more biocompatible than Acropars acrylic resin.

Key words: Biocompatibility - Human oral fibroblasts - Orthodontic materials - MTT assay

Keywords: Biocompatibility, Human oral fibroblasts, Orthodontic materials, MTT assay
Full-Text [PDF 271 kb]   (2749 Downloads)    
Type of Study: Research | Subject: General


XML     Print



Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 18, Issue 2 (Foll Text in Persian 2006) Back to browse issues page